The following article will guide you through using the C99-T02 cantilevers in Lineardraft, by providing you with:
- An annotated example with all limits for user adjustable values
- The system height and reach ranges for using the cantilevers in your design
C99-T02 Pull Off Cantilevers
![](https://s3-eu-central-1.amazonaws.com/euc-cdn.freshdesk.com/data/helpdesk/attachments/production/77137930733/original/ZThgPgwjet0jYQJs678ZNvffCwdLX_ybTQ.jpg?1694700985)
Design Limits
Please note: Where design limits are not available on the standard drawing, they have been provided by an external source, and are marked below in bold.
Standard:
- Minimum System Height: 855mm
- Maximum System Height: 1800mm
- Minimum Reach: 1857mm
- Maximum Reach: 3710mm
C99-T02 Push Off Cantilevers
![](https://s3-eu-central-1.amazonaws.com/euc-cdn.freshdesk.com/data/helpdesk/attachments/production/77137930772/original/6g-K84L0dX6xvs5iiaOgq-mTn7ByN8WmMA.jpg?1694701001)
Design Limits
Please note: Where design limits are not available on the standard drawing, they have been provided by an external source, and are marked below in bold.
Standard:
- Minimum System Height: 855mm
- Maximum System Height: 1800mm
- Minimum Reach: 1857mm
- Maximum Reach: 3710mm
C99-T02 Braced Pull Off Cantilevers
![](https://s3-eu-central-1.amazonaws.com/euc-cdn.freshdesk.com/data/helpdesk/attachments/production/77137930823/original/No1SjI5UHPiO0J3Xj9YZ2fjKTP5B12FdvQ.jpg?1694701019)
Design Limits
Please note: Where design limits are not available on the standard drawing, they have been provided by an external source, and are marked below in bold.
Standard:
- Minimum System Height: 855mm
- Maximum System Height: 1800mm
- Minimum Reach: 1857mm
- Maximum Reach: 5060mm
C99-T02 Braced Push Off Cantilevers
![](https://s3-eu-central-1.amazonaws.com/euc-cdn.freshdesk.com/data/helpdesk/attachments/production/77137930872/original/Ssj1wGGFdz8mO6kpbHiJK9mn38zvR4tG2g.jpg?1694701030)
Design Limits
Please note: Where design limits are not available on the standard drawing, they have been provided by an external source, and are marked below in bold.
Standard:
- Minimum System Height: 855mm
- Maximum System Height: 1800mm
- Minimum Reach: 1857mm
- Maximum Reach: 5060mm