The following article will guide you through using the C99-T07&T08 reach over cantilevers in Lineardraft, by providing you with:
- An annotated example with all limits for user adjustable values
- The system height and reach ranges for using the cantilevers in your design
C99-T07&T08 Reach Over Pull Off Cantilevers Clamp Above
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 1135mm
- Maximum System Height: 2500mm
- Minimum Reach: 1790mm
- Maximum Reach: 3100mm
C99-T07&T08 Reach Over Pull Off Cantilevers Clamp Below
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 1135mm
- Maximum System Height: 2500mm
- Minimum Reach: 1790mm
- Maximum Reach: 3100mm
C99-T07&T08 Reach Over Pull Off Cantilevers Contenary Clamp Below
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 1135mm
- Maximum System Height: 2500mm
- Minimum Reach: 1790mm
- Maximum Reach: 3100mm
C99-T07&T08 Reach Over Push Off Cantilevers Clamp Above
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 1135mm
- Maximum System Height: 2500mm
- Minimum Reach: 1675mm
- Maximum Reach: 3100mm
C99-T07&T08 Reach Over Push Off Cantilevers Clamp Below
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 1135mm
- Maximum System Height: 2500mm
- Minimum Reach: 1675mm
- Maximum Reach: 3100mm
C99-T07&T08 Reach Over Push Off Cantilevers Contenary Clamp Below
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
- Minimum System Height: 1135mm
- Maximum System Height: 2500mm
- Minimum Reach: 1675mm
- Maximum Reach: 3100mm
C99-T07&T08 Inverted Reach Over Pull Off Cantilevers Clamp Above
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 910mm
- Maximum System Height: 2500mm
- Minimum Reach: 1790mm
- Maximum Reach: 3100mm
C99-T07&T08 Inverted Reach Over Pull Off Cantilevers Clamp Below
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 910mm
- Maximum System Height: 2500mm
- Minimum Reach: 1790mm
- Maximum Reach: 3100mm
C99-T07&T08 Inverted Reach Over Pull Off Cantilevers Contenary Clamp Below
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 910mm
- Maximum System Height: 2500mm
- Minimum Reach: 1790mm
- Maximum Reach: 3100mm
C99-T07&T08 Inverted Reach Over Push Off Cantilevers Clamp Above
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 910mm
- Maximum System Height: 2500mm
- Minimum Reach: 1675mm
- Maximum Reach: 3100mm
C99-T07&T08 Inverted Reach Over Push Off Cantilevers Clamp Below
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 910mm
- Maximum System Height: 2500mm
- Minimum Reach: 1675mm
- Maximum Reach: 3100mm
C99-T07&T08 Inverted Reach Over Push Off Cantilevers Contenary Clamp Below
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 910mm
- Maximum System Height: 2500mm
- Minimum Reach: 1675mm
- Maximum Reach: 3100mm